NetScaler SDX Syslog Messages

NetScaler SDX 13.1 Release Syslog Message Reference

This reference document lists the syslog messages that are generated by NetScaler SDX.

Feature Category Severity Description Format
GUI CMD_EXECUTED INFO Logs the GUI command executed “User %s - Remote_ip %s - Command “%s” - Status “%s””
CLI CMD_EXECUTED INFO Logs the CLI command executed “User %s - Remote_ip %s - Command “%s” - Status “%s””
API CMD_EXECUTED INFO Logs the API command executed “User %s - Remote_ip %s - Command “%s” - Status “%s””
SNMP CMD_EXECUTED INFO Logs the SNMP command executed “User %s - Remote_ip %s - Command “%s” - Status “%s””
SNMP TRAP_SENT INFO Trap Sent Information “%s”
DEVICECONFIG CMD_EXECUTED INFO Logs the command executed on device “User %s - Remote_ip %s - Command “%s “ - Status “%s” - Message “%s””
EVENT RESOURCESTATENORMAL INFO The hardware or software resource error has been fixed and normal state has been restored; entityName and eventMessage show details “%s”
EVENT INTERFACEDOWN CRITICAL A network interface has gone down; entityName and eventMessage show details “%s”
EVENT DEVICEREMOVED INFO A managed device has been removed “%s”
EVENT HEALTHCOUNTERERROR CRITICAL Health Counter Error; entityName and eventMessage show specific failure information “%s”
EVENT MEMORYUSAGENORMAL INFO Memory utilization has returned to normal “%s”
EVENT FANSPEEDERROR CRITICAL Fan speed is either high or low “%s”
EVENT DEVICEREBOOTED INFO A managed device has failed to restart “%s”
EVENT DEVICEADDED INFO A managed device has been added “%s”
EVENT IPMISTATEERROR CRITICAL Intelligent Platform Management Interface (IPMI) utility is missing “%s”
EVENT CPUTEMPNORMAL INFO CPU temperature has returned to normal “%s”
EVENT INTERFACEUP INFO The network interface has returned to UP state; entityName and eventMessage show details “%s”
EVENT HSMSTATENORMAL INFO FIPS is operational,HSM state is back to normal “%s”
EVENT LOGINFAILURE CRITICAL This trap is sent when User Authentication fails. ‘entityName’ and ‘eventMessage’ will show specific failure information “%s”
EVENT DEVICEPOWERSTATECHANGED INFO Power state of a managed device has changed “%s”
EVENT DISKUTILIZATIONHIGH CRITICAL This trap is sent when the Disk utilization goes high. ‘entityName’ and ‘eventMessage’ will show specific failure information “%s”
EVENT DEVICESTATECHANGED MAJOR Instance state of a managed device has changed to down or out of service “%s”
EVENT BMCFIRMWAREVERSIONERROR CRITICAL BMC firmware is missing or the version is not supported “%s”
EVENT XENSSHFAILED CRITICAL SSH communication between the Management Service and XenServer has failed “%s”
EVENT SYSTEMTEMPNORMAL INFO System temperature has returned to normal “%s”
EVENT SDXVERSIONMISMATCHNORMAL INFO svm and platform version are matching “%s”
EVENT POWERSUPPLYNORMAL INFO Power Supply has returned to normal condition “%s”
EVENT SRSTATUSERROR CRITICAL This trap is sent when a storage repository status is not good. ‘entityName’ and ‘eventMessage’ will show specific failure information “%s”
EVENT BMCFIRMWAREVERSIONNORMAL INFO BMC firmware is detected or the version has returned to a supported version “%s”
EVENT SUBSYSTEMUP INFO A subsystem has returned to the UP state; entityName shows details “%s”
EVENT SDXVERSIONMISMATCHERROR CRITICAL There is a mismatch in svm and platform versions “%s”
EVENT SUBSYSTEMDOWN CRITICAL A subsystem has gone DOWN; entityName shows details “%s”
EVENT DEVICEREBOOTFAILED CRITICAL A managed device has failed to restart “%s”
EVENT POOLEDLICENSECAPACITYPARTIAL CRITICAL LicenseCapacityNormal; SDX is running on partial license capacity “%s”
EVENT CPUTEMPERROR CRITICAL CPU temperature error; entityName and eventMessage show specific failure information “%s”
EVENT HYPERVISORDISKUTILIZATIONHIGH MINOR Hypervisor disk utilization has exceeded the high threshold value “%s”
EVENT CPUUSAGENORMAL INFO CPU utilization has returned to normal “%s”
EVENT PHYSICALDRIVEFAILED CRITICAL Physical Drive Failed “%s”
EVENT DISKUTILIZATIONNORMAL INFO This trap is sent when the Disk utilization becomes normal. ‘entityName’ and ‘eventMessage’ will show specific failure information “%s”
EVENT DEVICEMODIFIED INFO An attribute of a managed device has been changed “%s”
EVENT VERSIONMATRIXMISMATCH INFO This trap is sent when version matrix mismatch is detected “%s”
EVENT POOLEDLICENSEGRACE MAJOR This trap is sent when license is on grace for more than 6(threshold) hours “%s”
EVENT LOGICALDRIVEFAILED CRITICAL Logical Drive Failed “%s”
EVENT DEVICEBOOTED INFO A managed device has failed to start “%s”
EVENT HEALTHMONITORPLUGINERROR CRITICAL This trap is sent when health monitor plugin (xsnsmonitor) is not installed on XenServer “%s”
EVENT INVENTORYFAILED CRITICAL XenServer inventory collection has failed “%s”
EVENT XENSSHNORMAL INFO SSH communication between the Management Service and XenServer has returned to normal “%s”
EVENT PASSWORDRECOVERYSUCCESS INFO Password has been recovered successfully “%s”
EVENT MEMORYUSAGEHIGH CRITICAL Memory utilization has exceeded the high threshold value. “%s”
EVENT SSLCERTTHRESHOLDNORMAL INFO sslCertThresholdNormal “%s”
EVENT HYPERVISORDISKUTILIZATIONNORMAL INFO Hypervisor disk utilization has returned to normal “%s”
EVENT XENPINGFAILED CRITICAL ICMP Ping between the Management Service and XenServer has failed “%s”
EVENT INVENTORYUP INFO Inventory has returned to normal condition “%s”
EVENT PASSWORDRECOVERYFAILED CRITICAL Password recovery has failed “%s”
EVENT SRSTATUSNORMAL INFO This trap is sent when a storage repository status becomes normal. ‘entityName’ and ‘eventMessage’ will show specific failure information “%s”
EVENT XENPINGNORMAL INFO ICMP Ping between the Management Service and XenServer has returned to normal “%s”
EVENT XENAPINORMAL INFO XenAPI communication between the Management Service and XenServer has returned to normal “%s”
EVENT PHYSICALDRIVENORMAL INFO Physical Drive Normal “%s”
EVENT SUBSYSTEMFAILED CRITICAL A subsystem has failed; entityName shows details “%s”
EVENT NETWORKCONFIGCHANGED INFO This trap is sent when Network Configuration is changed “%s”
EVENT POOLEDLICENSEGRACECRITICAL CRITICAL This trap is sent when license is on grace for more than 1(threshold) day(s) “%s”
EVENT DEVICEBOOTFAILED CRITICAL A managed device has failed to start “%s”
EVENT LOGICALDRIVENORMAL INFO Logical Drive Normal “%s”
EVENT VOLTAGENORMAL INFO Voltage has returned to normal “%s”
EVENT HEALTHCOUNTERNORMAL INFO Health Counter Error condition has returned to normal; entityName and eventMessage show details “%s”
EVENT XENHTTPFAILED CRITICAL HTTP communication between the Management Service and XenServer has failed “%s”
EVENT POOLEDLICENSECAPACITYNORMAL INFO LicenseCapacityNormal; SDX is running on proper license capacity “%s”
EVENT BACKUPFAILED MAJOR This trap is sent when the backup operation fails “%s”
EVENT XENHTTPNORMAL INFO HTTP communication between the Management Service and XenServer has returned to normal “%s”
EVENT RESOURCESTATEERROR CRITICAL A hardware or software resource error has occurred; entityName and eventMessage show specific failure information “%s”
EVENT FANSPEEDNORMAL INFO Fan speed has returned to normal “%s”
EVENT IPMISTATENORMAL INFO Intelligent Platform Management Interface (IPMI) utility is detected “%s”
EVENT HEALTHMONITORPLUGINNORMAL INFO This trap is sent when health monitor plugin (xsnsmonitor) is back to installed state on XenServer “%s”
EVENT XENAPIFAILED CRITICAL XenAPI communication between the Management Service and XenServer has failed “%s”
EVENT POOLEDLICENSEGRACENORMAL INFO License in not under Grace “%s”
EVENT TRAPCONFIGFAILURE CRITICAL This trap is sent when failure occurs in adding snmp trap destination “%s”
EVENT DEVICESTATECLEARED INFO Instance state of a managed device has changed to Up “%s”
EVENT CPUUSAGEHIGH CRITICAL CPU utilization has exceeded the high threshold value “%s”
EVENT POWERSUPPLYFAILED CRITICAL Power Supply error; entityName and eventMessage show specific failure information information “%s”
EVENT VOLTAGEERROR CRITICAL Voltage error; entityName and eventMessage show specific failure information “%s”
EVENT MPSUP INFO All subsystems are UP “%s”
EVENT SYSTEMTEMPERROR CRITICAL System temperature error; entityName and eventMessage show specific failure information “%s”
EVENT HSMSTATEERROR CRITICAL FIPS is non-operational, unable to determine HSM state “%s”
EVENT MPSDOWN INFO All subsystems are DOWN “%s”
EVENT SSLCERTTHRESHOLDBREACHED CRITICAL sslCertThresholdBreached;Certificate expiry “%s”
NetScaler SDX 13.1 Release Syslog Message Reference

In this article