ADC CLI Commands

pcp-profile

The following operations can be performed on “pcp-profile”:

rm set unset add show

rm pcp profile

Removes a pcp profile from the Citrix ADC.

Synopsis

rm pcp profile @ ...

Arguments

name Name of the pcp server.

Example

rm pcp profile prof1

set pcp profile

Modifies the specified parameters of a pcp profile.

Synopsis

set pcp profile \[-mapping \( ENABLED | DISABLED )] \[-peer \( ENABLED | DISABLED )] \[-minMapLife ] \[-maxMapLife ] \[-announceMultiCount <positive\_integer>] \[-thirdParty \( ENABLED | DISABLED )]

Arguments

name Name for the PCP Profile. Must begin with an ASCII alphanumeric or underscore (_) character, and must contain only ASCII alphanumeric, underscore CLI Users: If the name includes one or more spaces, enclose the name in double or single quotation marks (for example, “my pcpProfile” or my pcpProfile).

mapping This argument is for enabling/disabling the MAP opcode of current PCP Profile

Possible values: ENABLED, DISABLED Default value: ENABLED

peer This argument is for enabling/disabling the PEER opcode of current PCP Profile

Possible values: ENABLED, DISABLED Default value: ENABLED

minMapLife Integer value that identify the minimum mapping lifetime (in seconds) for a pcp profile. default(120s) Minimum value: 1 Maximum value: 2147483647

maxMapLife Integer value that identify the maximum mapping lifetime (in seconds) for a pcp profile. default(86400s = 24Hours). Minimum value: 1 Maximum value: 2147483647

announceMultiCount Integer value that identify the number announce message to be send. Default value: 10 Minimum value: 0 Maximum value: 65535

thirdParty This argument is for enabling/disabling the THIRD PARTY opcode of current PCP Profile

Possible values: ENABLED, DISABLED Default value: DISABLED

Example

set pcp profile prof1 -MAPPING ENABLED

unset pcp profile

Use this command to remove pcp profile settings.Refer to the set pcp profile command for meanings of the arguments.

Synopsis

unset pcp profile [-mapping] [-peer] [-minMapLife] [-maxMapLife] [-announceMultiCount] [-thirdParty]

add pcp profile

Creates a pcp profile.

Synopsis

add pcp profile \[-mapping \( ENABLED | DISABLED )] \[-peer \( ENABLED | DISABLED )] \[-minMapLife ] \[-maxMapLife ] \[-announceMultiCount <positive\_integer>] \[-thirdParty \( ENABLED | DISABLED )]

Arguments

name Name for the PCP Profile. Must begin with an ASCII alphanumeric or underscore (_) character, and must contain only ASCII alphanumeric, underscore CLI Users: If the name includes one or more spaces, enclose the name in double or single quotation marks (for example, “my pcpProfile” or my pcpProfile).

mapping This argument is for enabling/disabling the MAP opcode of current PCP Profile

Possible values: ENABLED, DISABLED Default value: ENABLED

peer This argument is for enabling/disabling the PEER opcode of current PCP Profile

Possible values: ENABLED, DISABLED Default value: ENABLED

minMapLife Integer value that identify the minimum mapping lifetime (in seconds) for a pcp profile. default(120s) Minimum value: 1 Maximum value: 2147483647

maxMapLife Integer value that identify the maximum mapping lifetime (in seconds) for a pcp profile. default(86400s = 24Hours). Minimum value: 1 Maximum value: 2147483647

announceMultiCount Integer value that identify the number announce message to be send. Default value: 10 Minimum value: 0 Maximum value: 65535

thirdParty This argument is for enabling/disabling the THIRD PARTY opcode of current PCP Profile

Possible values: ENABLED, DISABLED Default value: DISABLED

Example

add pcp profile prof1

show pcp profile

Displays the pcp server information.

Synopsis

show pcp profile []

Arguments

name Name of the pcp server.

Output

mapping This argument is for enabling/disabling the MAP opcode of current PCP Profile

peer This argument is for enabling/disabling the PEER opcode of current PCP Profile

minMapLife Integer value that identify the minimum mapping lifetime (in seconds) for a pcp profile. default(120s)

maxMapLife Integer value that identify the maximum mapping lifetime (in seconds) for a pcp profile. default(86400s = 24Hours).

announceMultiCount Integer value that identify the number announce message to be send.

thirdParty This argument is for enabling/disabling the THIRD PARTY opcode of current PCP Profile

devno count stateflag